Government agencies are serving the office, with the continuous development of society, the information processing capacity of government agencies is growing, traditional paper handling office has gradually meet the needs of the times. Since the second half of 2002, the government and administrative departments of the building wave of e-government at all levels across the country are on the rise. E-government is to achieve the government's large-scale information systems engineering, network (government offices) and the external network (public service) coexist and achieve the Government's internal information exchange and sharing of resources, and to provide services for the public. In recent years, the level of information coupled with the government to speed up the "open government, to promote e-government, accelerate the construction of government information" is an important development direction of e-government. E-government systems are gradually becoming the government and people exchange window. Due to the strong development of e-government, the working pressure of the system managers is growing, how to ensure stable and reliable e-government network system uninterrupted operation, raise an issue of efficiency of the public service and the government is facing.
In order to guarantee the smooth flow of information and sharing of data, network information centers to ensure coordinated management of the entire network node can monitor network operations to ensure the security of information networks, reliable, uninterrupted work, but must also ensure that subordinates subnet information site reliable, uninterrupted work. Ensure the smooth running of the entire computer network system, in order to ensure the smooth operation of the whole government. All links must be sure. It must have a stable and reliable power supply UPS power to do to protect the production line.
Ensure that the information network power line is safe, reliable, uninterrupted work must also take into account the impact on the grid system of UPS, UPS power supply to improve the quality of the grid and for efficient use of energy, not only saves energy, but also in the very effective thermal large extent on the atmospheric CO, SO, NO and dust, ash emissions, reducing pollution and protecting the environment; the government should have been advocating energy saving, environmental protection as a breakthrough in the transformation of economic growth mode and an important starting point, and unswervingly implement two binding targets, and strive to build a resource-saving and environment-friendly society; actively fulfill their social responsibilities.
UPS power demand of government information room description:
1, e-government system should transfer large amounts of confidential data every day, is government information in the highest efficiency. Therefore network reliability and stability are raised higher quality of service requirements. To ensure the security of information networks and reliable operation of the system, requiring two-way mains input (one mains, all the way oil machine).
2, the key to the power load required by the UPS load, critical data load with load capacity of at least 60KVA, reserve requirements for standby time up to 4 hours, requires very high reliability; UPS should have the dynamic data remote monitoring capabilities;
3, for emergency earthquake, fire, etc., can provide remote distal or proximal fast shutdown function, in order to avoid more serious damage occurs in an emergency.
4. UPS power module redundancy requirements designed to facilitate the expansion of the latter part of the power system.
5, requiring UPS uninterruptible power supply to the load equipment to provide clean energy, we must also take into account the efficient use of energy on the grid; effectively reduce and suppress harmonic pollution, and provide a good atmosphere for the reliable operation of critical load.
6, due to limited space to install the UPS and battery, requiring UPS suppliers, equipment placement to improve space utilization; calls for the full use of the limited space resources.
7, and the consideration of the bearing can be taken into account, to avoid damage to floor structure occurs.
Government Information room UPS Power Solution Brief
1, for the first term demand, suggested the use of ATS switch as a backup diesel generator sets, usually consider the issue standby unit automatically switches to the mains, and to meet the needs of users with high reliability, the design of two mains input; primary Road, electricity, road oil machine equipment; using ATS switch;
2, paragraph 2 to meet the user in order to make the whole system is easy to load, easy to shunt and more distant connections. A whole of distribution, we recommend the use of sub-critical load equipment grade levels, low-voltage AC power distribution cabinet power distribution, computer room air conditioning, lighting, fire protection, elevators, etc. directly to the level of low-voltage AC power distribution cabinet; the key to the data load device UPS power supply connected to the adoption of the secondary low voltage distribution cabinet; based on the special requirements of critical data load power, the power needs of the entire system must employ highly parallel redundant power supply module program capacity over the function.
3, for the needs of the first three, woqiquan Uranus (Uranus) Series Industrial UPS EPO provides emergency shutdown function keys provide fast shutdown proximal and distal Network Remote while providing emergency shutdown functions are available to operate. As long as this function once started, UPS can quickly shut down without the normal shutdown operating procedures according to an orderly shutdown. In order to save time in an emergency, to avoid the expansion of disasters.
4. The demand for item 4, Uranus (Uranus) Series Industrial UPS modular design, users only need to purchase any power UPS host again, you can achieve "N + X" and the upgrade and expansion of fault tolerance. Most important feature of Uranus (Uranus) Series Industrial UPS is that a host of different power UPS can achieve N + X redundancy and machine.
Using N + X redundant operation, the power loads are supported by the new technology to achieve N + X redundancy. Load power array are worried mean all hosts in parallel operation and load average burden. Any one UPS fails, can automatically from the system to ensure the normal operation, woqiquan Uranus (Uranus) Series Industrial UPS design not only redundant, but also between different host UPS power and machine function can also be achieved, any damage to a UPS host interfering greatly improve system reliability, availability.